  Datasheet File OCR Text:
 MCC
Micro Commercial Components
TM
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
MBR5200
Features
* * * * Low Switching Noise Low Forward Voltage Drop High Current Capability High Surge Current Capability
5 Amp Schottky Barrier Rectifier 200 Volts
DO-201AD
Maximum Ratings
* * Operating Temperature: -50C to +150C Storage Temperature: -50C to +150C
MCC Catalog Number
Device Marking
MBR5200
MBR5200
Maximum Recurrent Peak Reverse Voltage 200V
Maximum RMS Voltage
Maximum DC Blocking Voltage 200V
D
140V
A Cathode Mark B
Electrical Characteristics @ 25C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage IF(AV) IFSM 5.0A 120A TA = 85C 8.3ms, half sine
D
C
VF
1.0V
IFM = 5.0A; TA = 25C*
DIM A B C D INCHES MIN .287 .189 .048 1.000
DIMENSIONS MM MIN 7.30 4.80 1.20 25.40
Maximum DC Reverse Current At Rated DC Blocking Voltage
IR
0.1mA
TA = 25C
MAX .374 .208 .052 ---
MAX 9.50 5.30 1.30 ---
NOTE
*Pulse test: Pulse width 300 sec, Duty cycle 2%
www.mccsemi.com
Revision: 3 2003/04/30
MBR5200
Figure 1 Typical Forward Characteristics 20 10 6 4 2 Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts .8 1.0 1.2 .02 .01 .006 .00 4 .002 .001 20 50 75 25C 10 6 4 2 1 .6 .4 .2 TJ=25C Amps .1 .06 .04
MCC
Micro Commercial Components
Figure 2 Typical Reverse Characteristics
TM
100 Volts
125 150
175
Figure 3 Forward Derating Curve 6
Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
5 150 4
Figure 4 Maximum Non-Repetitive Forward Surge Current
125 3 Amps 2 Amps 1 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 50 75 100 C Average Forward Rectified Current - Amperes versus Ambient Temperature - C 125 150 175 25 5 0 100 75 50
1
2
4
6
8 10 20 Cycles
40
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
Revision: 3 2003/04/30